Gas well is equipped with X-mas tree wing valve of FF 10K Temperature classification U rated. Maximum flowing wellhead temperature was observed ~ 270-275 degF, which is bit higher than U temperature class (250 degF). During pressure testing, found valve not holding pressure.
How differential thermal expansion due to temperature changes could have any effect on X-mas tree valves to leak.
------------------------------
Lajpat Rai
Petroleum Engineer
United Energy Pakistan Ltd
Karachi City
------------------------------