Well Integrity Technical Section

 View Only
  • 1.  Use of VR plugs

    Posted 07-08-2015 04:13 AM

    Folks,

     

    I am trying to gauge peoples opinions on using VR plugs as a long term barrier where no gate valve is installed? The case that I am thinking of, is on the non-active side of the wellhead, where you fit a VR plug in place, followed by a blanking plate, complete with a NPT fitting and needle valve and pressure gauge.

     

    Depending on your response, would it matter if this is the “A”, “B”, “C”, etc. annuli



    ------------------------------
    Stuart Wardlaw
    Well Engineer
    ------------------------------



  • 2.  RE: Use of VR plugs

    Posted 07-09-2015 03:02 AM
    Stuart,
    If you're going to do this, which is quite acceptable, install the VR plug on one side only and put a Gate valve on the other side. That way, you can always circulate the well as required for whatever reason.
    And it's good for any annulus.

    Regards
    Stuart Liddle
    Consultant

    ------Original Message------

    Folks,

     

    I am trying to gauge peoples opinions on using VR plugs as a long term barrier where no gate valve is installed? The case that I am thinking of, is on the non-active side of the wellhead, where you fit a VR plug in place, followed by a blanking plate, complete with a NPT fitting and needle valve and pressure gauge.

     

    Depending on your response, would it matter if this is the “A”, “B”, “C”, etc. annuli



    ------------------------------
    Stuart Wardlaw
    Well Engineer
    ------------------------------



  • 3.  RE: Use of VR plugs

    Posted 07-09-2015 05:56 AM

    Stuart,

    Thanks for your input. Indeed, this is the example that I was thinking of when I wrote the post, and should have been a little more clearer

    Thanks

    Stuart

    ------------------------------
    Stuart Wardlaw
    Well Engineer
    ------------------------------




  • 4.  RE: Use of VR plugs

    Posted 07-09-2015 05:42 AM

    Stuart,

    There shouldn't be anything wrong with a VR plug as a long term barrier in principle, but there are a few things puzzling me:

    • You're installing a barrier element without testing & qualifying it (your annulus is not live).
    • Then you put your blanking plug as a backup, with a pressure gauge to detect whether the VR plug has failed.
    • If the annulus becomes live at some point you won't know it unless the VR plug fails or you remove it.
    • If there is no pressure, you can always remove the blanking plate then play with the VR plug through a lubricator, but what if you measure a leak through your gauge? Then what do you do (since you know your primary and secondary barriers have failed but not your third one - the blanking plate, valve and gauge)?

    I would feel more comfortable with doing this on B+ annuli but not the A annulus: it has a tendency to fail (packer and tubing mostly) and most failures will result in a large potential flow rate. If outer annuli come live, the majority of leaks will be small (through cement), so easier to control if the VR plug fails.

    Best regards,

    Matteo


    ------------------------------
    Matteo Loizzo
    Well integrity consultant
    Berlin
    ------------------------------




  • 5.  RE: Use of VR plugs

    Posted 07-09-2015 05:50 AM

    Matteo,

    Thanks for your reply. I could have been more specific in my original posting and apologise for this. This would only be on the non-active side, while the active side would have a gate valve, etc. in place.

    Thanks

    Stuart

    ------------------------------
    Stuart Wardlaw
    Well Engineer
    ------------------------------




  • 6.  RE: Use of VR plugs

    Posted 07-09-2015 07:15 AM

    Generally I agree that it's an acceptable barrier in the operations I've been involved with, particularly short - medium term, however there's some interesting issues.

    1. If used in the A annulus is it installed in a well with a packer and kill weight fluid or is there no packer and a live annulus. What are your "two barriers" & your barrier policy? Packer fluid isn't always kill weight!

    2. I'm not sure what type of thread a VR plug has, perhaps LP (NPT?) and typically < 2".  This leads to questions about the long term.  integrity of the thread, similar to questions raised about BTC, STC, LTC, EUE,etc. What sealant / lubricant / tape , if any? 

    3. What pressure rating is the casing head or spool? I think 2" threaded connections are limited to 3k or maybe 5k. The VR is just <2" so ???

    4. I recall hot tapping some solid bull plugs way back and probably the VR plugs too to check for pressure. Always run a tapped bull plug in that scenario over a VR plug.

    5. I also recall there are different styles of VR plugs. One's solid. Another type I think you can insert what I call a Vaetrix nipple (I've also heard it called a Taylor plug) to check for pressure under the VR. This results in additional potential leak paths (o-rings, Check valve, etc).

    6. The VR plugs are tested in the factory as part of the head / spool manufacture however in the field it might be removed for circulation and  it might not be possible to re validate the re installation.

    7. I agree could be used in any annulus subject to a P limit (<= 5k) but usually on A annulus it's useful having pressure or flow / pump access on both sides.

    Terry Greaney

    Consultant

    Brisbane




  • 7.  RE: Use of VR plugs

    Posted 07-15-2015 05:20 AM

    Terry, thanks for your input and raising a few interesting points for me to clarify with both clients and suppliers in the future



    ------------------------------
    Stuart Wardlaw
    Well Engineer
    ------------------------------